> For the complete documentation index, see [llms.txt](https://support.senterasensors.com/home/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://support.senterasensors.com/home/65r-sensor-user-guide/65r-sensor/data-offload/offload-process/offload-process-mac.md).

# Offload Process - Mac

## Getting Started

The 65R stores the imagery on an internal solid state hard drive that is not removable from the sensor. Use the process outline below to access the collected data.&#x20;

{% hint style="warning" %}
Imagery is NOT stored on the micro SD card.&#x20;
{% endhint %}

## Instructions

{% stepper %}
{% step %}

### Power On Sensor

Power the 65R using the AC adapter or keep it attached to the aircraft and turn the aircraft on.&#x20;

Then wait for the LEDS on the sensor to do the following:

<table><thead><tr><th width="217">Power Method</th><th>LED Behavior</th></tr></thead><tbody><tr><td>AC Power Adapter</td><td>Flashing Red</td></tr><tr><td>Drone Power</td><td>Solid Green (Requires GPS Fix)<br>Solid Red (After 2 minutes w/o GPS) </td></tr></tbody></table>

This verifies that the sensor is fully booted and ready for data offload.

<div data-with-frame="true"><figure><img src="https://3675182560-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FXxc0lOfDa92aCfFa5lb4%2Fuploads%2FVhVjV9qRMU7xgtHuLRXL%2Fimage.png?alt=media&amp;token=bbbdce71-8a04-49d5-b0de-a9ff3dc5ed3b" alt=""><figcaption></figcaption></figure></div>
{% endstep %}

{% step %}

### Connect USB Cable to Sensor and Computer

Connect the sensor to the computer using a USB cable.

{% hint style="info" %}
Use the USB-C port on the sensor not the USB-C port on the top of the gimbal.
{% endhint %}

{% hint style="warning" %}
Use the [USB-C Cable provided with the 65R](https://www.amazon.com/Anker-Powerline-Pull-up-Resistor-MacBook/dp/B01MZIPYPY?th=1). This cable gives the best and most reliable performance.&#x20;
{% endhint %}

<div data-with-frame="true"><figure><img src="https://3675182560-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FXxc0lOfDa92aCfFa5lb4%2Fuploads%2FIpXjQuKxS3qCFQM165Oq%2Fimage.png?alt=media&amp;token=c5ee9971-229c-460c-be9d-81e2234876f9" alt=""><figcaption></figcaption></figure></div>
{% endstep %}

{% step %}

### Open a Finder Window

Once the 65R is fully booted it will appear as a network location in the left hand menu of the Finder window.

{% hint style="info" %}
If the 65R doesn't automatically show up, select the Network option under Locations, as it may appear there the first time the 65R is connected.

If there is a SENTERA-65R-SMB as well, select SENTERA-65R.
{% endhint %}

{% hint style="info" %}
If the 65R can't be connected to after a few minutes try the following: - Turn off/disconnect any Wi-Fi or Ethernet connections that have internet access. - Verify the USB cable being used is the provided cable or one of the listed [compatible cables.](https://sentera.gitbook.io/65r-sensor-user-guide/65r-sensor/whats-in-the-box/replacement-cables)
{% endhint %}

<div data-with-frame="true"><figure><img src="https://3675182560-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FXxc0lOfDa92aCfFa5lb4%2Fuploads%2FnCEm1mGlE5wa8GmKqMel%2Fimage.png?alt=media&amp;token=87da3ea9-c555-479f-b46f-644706cc3455" alt=""><figcaption></figcaption></figure></div>
{% endstep %}

{% step %}

### Select Data Folder

<div data-with-frame="true"><figure><img src="https://3675182560-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FXxc0lOfDa92aCfFa5lb4%2Fuploads%2FJBV8dblCFXBxK87MYvWd%2Fimage.png?alt=media&amp;token=0f68e222-b49b-45bf-bbe8-582d1c17e709" alt=""><figcaption></figcaption></figure></div>
{% endstep %}

{% step %}

### Select Snapshots Folder

<div data-with-frame="true"><figure><img src="https://3675182560-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FXxc0lOfDa92aCfFa5lb4%2Fuploads%2F6Dqsn4zIaoEdv7QakEMc%2Fimage.png?alt=media&amp;token=0a5a959d-bf76-4130-b2b2-62cf20f9971f" alt=""><figcaption></figcaption></figure></div>
{% endstep %}

{% step %}

### Select Session Folder

Session folders are the folders where the imagery is stored for each flight.&#x20;

{% hint style="info" %}
If the 65R is not power cycled between flights that are intended to be separate (i.e. not a battery swap) all of the photos from both flights will be stored in the same session folder.&#x20;
{% endhint %}

<div data-with-frame="true"><figure><img src="https://3675182560-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FXxc0lOfDa92aCfFa5lb4%2Fuploads%2FjAB5uMxrxF4MXconXZSb%2Fimage.png?alt=media&amp;token=977d1877-32bf-43f7-85bb-35bc3c5aa62f" alt=""><figcaption></figcaption></figure></div>
{% endstep %}

{% step %}

### Copy Folder

{% hint style="warning" %}
Ensure that you always copy-paste (cmd+C) and not cut-paste (cmd+X). Using cut-paste can lead to data loss that can not be undone.
{% endhint %}

<div data-with-frame="true"><figure><img src="https://3675182560-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FXxc0lOfDa92aCfFa5lb4%2Fuploads%2FzHxnk3MBsI2pPQWD1KeT%2Fimage.png?alt=media&amp;token=b05db1a0-9311-4def-872d-e608589edf25" alt=""><figcaption></figcaption></figure></div>

<div data-with-frame="true"><figure><img src="https://3675182560-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FXxc0lOfDa92aCfFa5lb4%2Fuploads%2FTlnvGPyNQI0hKltZH3vz%2Fimage.png?alt=media&amp;token=a4b3e07c-612b-45ad-b2d1-dbcd20bbae78" alt=""><figcaption></figcaption></figure></div>
{% endstep %}

{% step %}

### Eject Sensor

{% hint style="info" %}
Use the eject button to release the sensor from the OS. This provides the best reliability.&#x20;
{% endhint %}

<div data-with-frame="true"><figure><img src="https://3675182560-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FXxc0lOfDa92aCfFa5lb4%2Fuploads%2F9cCZ0uCg07fhiXXob5Lx%2Fimage.png?alt=media&amp;token=9fc4f21d-91e9-4c16-bad2-432cd1eadabc" alt=""><figcaption></figcaption></figure></div>
{% endstep %}
{% endstepper %}


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter, and the optional `goal` query parameter:

```
GET https://support.senterasensors.com/home/65r-sensor-user-guide/65r-sensor/data-offload/offload-process/offload-process-mac.md?ask=<question>&goal=<endgoal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is optional and describes the broader end goal you are ultimately trying to accomplish on behalf of the user. GitBook uses it to tailor the answer towards what is most useful for that goal.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.