Offload Process For MacOS
6X Series Sensors Data Offload For MacOS
Last updated
6X Series Sensors Data Offload For MacOS
Last updated
Sentera 6X Series Sensors
6X Product PagePurchase 6X MultispectralPurchase 6X ThermalPurchase 6X Thermal ProSentera Calibrated Reflectance Panel
Purchase Reflectance PanelThe 6X stores the imagery on an internal solid state hard drive that is not removeable from the sensor. Use the process outline below to access the collected data.
Imagery is NOT stored on the micro SD card.
Power the 6X using the AC adapter or keep it attached to the aircraft and turn the aircraft on.
When using the AC power supply, connect the cable to the 6X first, then connect the adapter to the outlet.
Then wait for the LEDS on the sensor to do the following:
AC Power Adapter
Flashing Red
Drone Power
Solid Green (Requires GPS Fix) Solid Red ( After 2 minutes w/o GPS)
This verifies that the sensor is fully booted and ready for data offload.
Connect the sensor to the computer using a USB cable.
Use the USB-C port on the sensor not the USB-C port on the top of the gimbal.
Use the USB-C Cable provided with the 6X. This cable gives the best and most reliable performance.
Once the 6X is fully booted it will appear as a network location in the left hand menu of the Finder window.
If the 6X doesn't automatically show up, select the Network option under Locations, as it may appear there the first time the 6X is connected.
If there is a SENTERA-6X-SMB as well, select SENTERA-6X.
If the 6X can be connected to after a few minutes try the following: - Turn off/disconnect any Wi-Fi or Ethernet connections that have internet access. - Verify the USB cable being used is the provided cable or one of the listed compatible cables.
Select the 6X location and then select the data folder.
Session folders are the folders where the imagery is stored for each flight.
If the 6X is not power cycled between flights that are intended to be separate (i.e. not a battery swap) all of the photos from both flights will be stored in the same session folder.
Use the eject button to release the sensor from the OS. This provides the best reliability.